The rate at which the controller can change the motor's StepperVelocity.
StepperRescaleFactor to convert the units of this property into more intuitive units such as rotations or degrees.
For more information about StepperAcceleration, visit our Stepper API Guide.

|
|
Device In Device # Identification |
|
|
error in (no error) error in can accept error information wired from VIs previously called. |
|
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
code code is the error or warning code. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
source source describes the origin of the error or warning. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
Acceleration The acceleration value 1062_0 (ver: 101) Unipolar Stepper Controller: Min: 140.625 Max: 8859.375 Default: 200
1062_1 (ver: 101, 102) Unipolar Stepper Controller: Min: 140.625 Max: 8859.375 Default: 200
1063_0 (ver: 100) Bipolar Stepper Controller: Min: 4000 Max: 1020000 Default: 10000
1063_1 (ver: 100, 101) Bipolar Stepper Controller: Min: 4000 Max: 1020000 Default: 10000
1067_0 (ver: 200, 201, 202, 203, 204, 205, 206) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1000_0 (ver: 100, 101) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1000_0 (ver: 110, 111, 112, 113, 114, 121, 122) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1001_0 (ver: 100, 101) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1001_0 (ver: 110, 111, 112, 113, 114, 115, 121, 122) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1002_0 (ver: 101, 102) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1002_0 (ver: 110, 111, 112, 113, 114, 121, 122) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1003_0 (ver: 100, 101) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1003_0 (ver: 110, 111, 112, 113, 114, 121, 122) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1003_1 (ver: 201, 221, 222) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1005_0 (ver: 100) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000
STC1005_0 (ver: 110, 111) Bipolar Stepper Controller: Min: 2 Max: 10000000 Default: 10000 |
|
|
Device Out Same as Device In |
|
|
error out error out passes error or warning information out of a VI to be used by other VIs. |
|
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
code code is the error or warning code. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
source source describes the origin of the error or warning. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |